儀表簡(jiǎn)介
D34-W 低功率因數(shù)瓦特表(功率表)為電動(dòng)系儀表,供直流電路中測(cè)量小功率或交流50~60Hz電路中(在低功率因數(shù)場(chǎng)合下)測(cè)量交流功率之用,也可用于測(cè)磁裝置上測(cè)量磁性材料的鐵損及電機(jī)、變壓器空載損耗功率。該儀表適用于周圍環(huán)境溫度23±10℃、相對(duì)濕度25%~80%的條件下使用,且空氣中不應(yīng)含有腐蝕性氣體。
技術(shù)特性
1、測(cè)量范圍與功耗:
測(cè)量范圍 50Hz消耗(VA) 刻度代碼
25/50/100V 0.25/0.5A 0.75/1.5/3 2.64/2.64 125
50/100/200V 0.25/0.5A 1.5/3/6 2.64/2.64 100
75/150/300V 0.25/0.5A 2.25/4.5/9 2.64/2.64 150
150/300/600V 0.25/0.5A 4.5/9/18 2.64/2.64 150
25/50/100V 0.5/1A 0.75/1.5/3 2.81/2.81 100
50/100/200V 0.5/1A 1.5/3/6 2.81/2.81 100
75/150/300V 0.5/1A 2.25/4.5/9 2.81/2.81 150
150/300/600V 0.5/1A 4.5/9/18 2.81/2.81 150
25/50/100V 1/2A 0.75/1.5/3 2.73/2.73 100
50/100/200V 1/2A 1.5/3/6 2.73/2.73 100
75/150/300V 1/2A 2.25/4.5/9 2.73/2.73 150
150/300/600V 1/2A 4.5/9/18 2.73/2.73 120
25/50/100V 2.5/5A 0.75/1.5/3 3.10/3.10 125
50/100/200V 2.5/5A 1.5/3/6 3.10/3.10 100
75/150/300V 2.5/5A 2.25/4.5/9 3.10/3.10 150
150/300/600V 2.5/5A 4.5/9/18 3.10/3.10 150
25/50/100V 5/10A 0.75/1.5/3 3.12/3.12 100
50/100/200V 5/10A 1.5/3/6 3.12/3.12 100
75/150/300V 5/10A 2.25/4.5/9 3.12/3.12 150
150/300/600V 5/10A 4.5/9/18 3.12/3.12 150
2、準(zhǔn)確度等級(jí):0.5級(jí)
3、工作位置:水平位置
4、響應(yīng)時(shí)間:大不于4S
5、標(biāo)度尺長(zhǎng)度:130mm
6、額定功率因數(shù):cosφ=0.2
7、基本誤差:當(dāng)使用條件符合周圍環(huán)境溫度為23℃±2℃,溫度為40%~60%RH時(shí),儀表的基本誤差在標(biāo)度尺工作部分的所有分度線上不超過(guò)測(cè)量上限的±0.5%。
8、環(huán)境溫度引起的改變量:當(dāng)周圍環(huán)境溫度自23℃±2℃改變至規(guī)定的工作溫度范圍(23℃±10℃)內(nèi)任一溫度時(shí),由此引起儀表指示值的改變?cè)趽Q算為溫度每改變10℃時(shí)不超過(guò)測(cè)量上限的±0.5%。
9、外磁場(chǎng)引起的改變量:儀表由于0.4kA/m,交流或直流的外磁場(chǎng)影響,其指示值的改變不超過(guò)測(cè)量上限的±1.5%。
9、儀表在額定電壓、額定電流、額定頻率下,功率因數(shù)從0.2下降到0.1(感性)使用時(shí),儀表指示值的改變不超過(guò)測(cè)量上限±0.5%
10、安全要求:接線端與外殼之間能耐受交流50Hz、2kV、1min的電壓試驗(yàn),絕緣電阻不小于5MΩ。